Detailed specifications
Accuracy class C1,C2
Output sensitivity ( = FS )mV/V 2.0 ± 0.01
Maximum capacity ( Emax )t 10, 20, 30, 50,100
Max.number of load cell intervalsnLC 1000 2000
Ratio of min. LC verification intervalY = Emax / vmin 3000 5000
Combined Error %FS ≤± 0.0500 ≤± 0.0300
Minimum dead loadOf Emax 0%
Safe overloadof Emax 150 %
Ultimate overloadof Emax 300 %
Zero balanceof FS < ± 1.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum 18V
Input resistance Ω 770 ± 30
Output resistance Ω 700 ± 7
Insulation resistance MΩ ≥5000 ( at 50VDC )
Compensated temperature °C -10 ~+40
Operating temperature °C -35 ~ +65
Storage temperature -40 ~ +70
Element material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP67
Recommended torque on fixation Nm
M8:25 M10:50 M12:75